User Controls
Posts by stl1
-
2019-04-11 at 6:37 PM UTC in DietPiano seduces his mon after using methIf you insist.
Just hope I'm not taken by then!
Don't blow this opportunity while I'm giving you the chance. -
2019-04-11 at 6:10 PM UTC in DietPiano seduces his mon after using methTee Hee, you have my permission to try to seduce me but, please, forget the meth.
Start by sending nekkid pictures! -
2019-04-11 at 6:08 PM UTC in Do you shave your arm pits & pubes?DON'T send nekkid pictures!
-
2019-04-11 at 6:05 PM UTC in Digital thermostats are fucked
-
2019-04-11 at 6:05 PM UTC in Digital thermostats are fucked
Originally posted by Jiggaboo_Johnson Mine are all labeled, any electrician worth his salt will have them labeled and any householder worth his salt would too.
Worst case you're an idiot and have to reset a few clocks, first world problem. AC/Heater is usually ones marked 30A.
Wrong, Kilowatt breath! Obviously, you are referring to an electric furnace while I was referring to a gas furnace (by far the most prevalent in St. Louis). Low voltage wiring will be the same regardless at t-stat.
An electric furnace usually will have breakers on the furnace and wouldn't normally require going to the fuse (circuit breaker) box. If the OP's problem is with an electric furnace, his most likely problem is with a sequencer. This should be handled by a qualified serviceman as you are now playing with 240 volts rather than the 24 volts used for t-stats. Also, a residential gas furnace is almost always powered by a 120 volt 15 amp breaker. Only in Texas and very southern states would you find an electric furnace powered through a 30 amp 240 volt breaker. One 5 kw element will draw approximately 20 amps by itself. A 20 kw furnace would be powered by a 100 amp breaker. -
2019-04-11 at 5:16 PM UTC in Digital thermostats are fuckedWhich breaker?
I can just see Boo walking around the house resetting all the clocks on his stove, microwave, etc. because the breakers weren't labeled and the furnace was the last breaker.
Boo buys Hunter t-stats. -
2019-04-11 at 5:10 PM UTC in Digital thermostats are fuckedwtf?
-
2019-04-11 at 5:09 PM UTC in There is always like 7 cars lined up in the drive through pharmacy...Maybe they just figured, with the way you look, you really wouldn't be needing the Viagra any time soon.
LOLOLOLOLOLOLOL -
2019-04-11 at 5:05 PM UTC in Digital thermostats are fucked
-
2019-04-11 at 5:02 PM UTC in FAO wellhung lolIt has been a little more pleasant of late.
-
2019-04-11 at 4:48 PM UTC in Digital thermostats are fuckedTake the front off the thermostat (or, on really cheap models you'll need to remove from the wall) to get to the low voltage wiring. You will normally find 4 wires color coded red, green, yellow and white. The red wire is incoming power. The green wire turns on the furnace blower at high speed (heat comes on at a lower speed through, normally these days, a circuit board at the furnace). The yellow wire turns on the outdoor A/C condensing unit. The white wire turns on the furnace. If there is a fifth wire, it will be for a neutral to power the thermostat then only using the batteries as backup. The fifth wire could also be for a reversing valve but only on a heat pump system.
Removing the white wire should stop your furnace. If not, your problem probably lies within your furnace such as a stuck gas valve although you may possibly have a short between the red and white wire somewhere. A stuck gas valve would require turning the gas supply valve off. It should be located just outside of the furnace in the incoming gas line.
The very easiest way to stop the system is to turn off the switch on the side of the furnace. It should look just like a light switch. If the gas continues to flow, you have a stuck gas valve (very rare...I can only remember finding one in my HVAC career and it was on a water heater and involved a valve that continued working with the pilot blown out).
Hope this helps! PM if need more help. If you're going to replace the thermostat, my recommendation would be a Honeywell thermostat. -
2019-04-11 at 4:27 PM UTC in How can i trick a girl into liking meYou should have put that bitch over your knee and reddened her fat ass for her while repeatedly saying "BAD GIRL!!!", Mikey.
Be like dad. -
2019-04-10 at 10:06 PM UTC in Jail in about 48 hoursHung like a Little Pony?
Don't be dropping that soap in the shower! -
2019-04-10 at 6:33 PM UTC in Well the Mueller report is in the hands of the AG, now what?
-
2019-04-10 at 6:17 PM UTC in Atlantis Discovered?
-
2019-04-10 at 5:14 PM UTC in ASSANGE TO GET FUCKED LIVESTREAM
Originally posted by Narc This is the point. US/UK intelligence will happily bargain enemy troop movements from local snitches and all manner of other sources. Its OK for them but not when the shoes on the other foot. I wouldn't mind if these were wars where foreign troops were potentially landing on our shores, but thats definitely not the case in any of these wars. They are nothing g more than wars dreamed up against near defenceless countries so that rich men can sell arms and military supplies to the armed forces using our tax dollars. Afaic anybody who signs up to fight in one of these fraudulent wars has no right to complain about anything. They can't even man up enough to demand their own fair share of the pie from their masters that they are risking leaving their families behind for. Fucking mugs the lot of them.
What I see as one of the main reasons we are still over in the middle east is to send a message that anyone contemplating another 9-11 will have the USA up their ass for a long, long time. -
2019-04-10 at 5:03 AM UTC in I have to pull my head from my assDo you mind if I hold my nose?
-
2019-04-09 at 6:49 PM UTC in RegretsHow disappointed are you with the state of your past? Things you regret doing, things you regret never having done.
-
2019-04-08 at 9:59 PM UTC in We just had a downpour and it's still drizzling
-
2019-04-08 at 9:49 PM UTC in Do you have nice hands?