2022-01-27 at 4:54 AM UTC
RIPtotse
victim of incest
[my adversative decurved garbo]
Makes mein house hotter than 2 bitches on a bitch boat
Or however that saying goes
Jonts?
2022-01-27 at 1:07 PM UTC
Turn the thermostat down.
2022-01-27 at 5:50 PM UTC
What type of thermostat do you have? If it's one of the old mechanical thermostats (think round, gold Honeywell T87F) there is a feature called a heat anticipator that needs to be adjusted to match the amp draw of the circuit. Luckily, you should find the proper heat anticipator setting on your furnace tag (usually located on a side wall inside the furnace behind the upper door). Remove the T-stat outer cover to find the moveable heat anticipator indicator. Move it to match the setting indicated on your furnace.
The function of the heat anticipator is to supply false heat to the T-stat because the furnace continues to blow hot air after it shuts off for a minute or so and the false heat "anticipates" this added heat. The wrong setting causes the T-stat to turn off either too early or too late causing the home to run too warm or cold. There is no adjustable setting for the A/C.
Disregard above if you have a newer, digital T-stat as the heat anticipation is done automatically on those. You may need to set for the proper type of heater (forced air gas/electric, hot water boiler, steam boiler, heat pump, etc.)
The following users say it would be alright if the author of this
post didn't die in a fire!
2022-01-27 at 6:24 PM UTC
RIPtotse
victim of incest
[my adversative decurved garbo]
I have a digital one Mr hvac.
I know how to set it and it works fine I was just hot
2022-01-27 at 7:12 PM UTC
You're welcome, Mr. Ungrateful.
Try to help some people.